Products Description
Armored control cables are fitted with metal armour layer, used for control-signal and low-power circuits.
The armour provides mechanical protection against crushing, impact and abrasion. Widely laid underground, on ships and offshore platforms. Common armour types include SWA steel wire armour and STA steel tape armour.
Multicore structure for control signals and auxiliary power. Outer sheath resists oil, moisture and chemical exposure. Suitable for harsh installation conditions where cables face physical damage risk.
|
Rated Voltage |
450/750 V |
|
Conductor |
0.75-10 mm² |
|
Temperature Range |
-20℃ ~ +80℃ |
|
Insulation resistance |
2000 MΩ·km |
|
Minimum bending radius |
12× cable OD (armoured) |
Application

Certificate
ISO Quality Management System Certificate
Verification to IEC 60227-5:2024,
EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021

|
1.Construction |
|||||||
|
S/N |
Construction |
Requirement |
|
||||
|
1 |
Conductor |
1 Class 1 copper conductor |
|||||
|
2 |
Insulation |
XLPE |
|||||
|
3 |
Inner sheath |
PVC |
|||||
|
4 |
Armor |
Galvanized steel wire armor |
|||||
|
5 |
Sheath |
PVC |
|||||
|
2. Cable identification Core identification: Four cores: Blue, Black, Brown, Gray 16:+ Twelve cores: white + number code 3. Standard compliance ICEA S-75-381 |
|||||||
|
4.Application |
|||||||
|
S/N |
Item |
Technical requirement |
|||||
|
1 |
Rated voltage |
AC 450/750V |
|||||
|
2 |
Operating temperature |
'-15~90℃ |
|||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/km |
|
|
1 |
4×1.5 |
1/1.37 |
1.37 |
0.6 |
1.5 |
14.1 |
343 |
|
2 |
16×1.5 |
1/1.37 |
1.37 |
0.6 |
1.7 |
21.3 |
855 |
|
5. Electrical characteristics |
|||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
|||||
|
1 |
4×1.5 |
12.1 |
3/5 |
||||
|
2 |
16×1.5 |
12.1 |
3/5 |
||||
Huayu Armored Control Cables Benefit
- SWA/STA metal armour, stands up to impact, crush and digging damage on site
- 450/750V rated, stable power & control signal transmission over long runs
- Class 5 tinned copper conductors, works for tough routing and frequent bending
- Good mechanical protection for direct-burial, deck and offshore exposed wiring
- Insulation resistance ≥2000MΩ·km, solid long-term working performance
- Operating range -20℃ ~ +80℃, oil and moisture resistant
- Optional PVC, LSZH and flame-retardant outer sheath
- Full batch electrical check carried out before shipment

FAQs
Q1: What armour types are available for control cables?
A: SWA steel-wire armour and STA steel-tape armour are both available.
Q2: Where can armored control cables be installed?
A: Suitable for direct burial, process plants and offshore platforms.
Q3: What sheath choices do I have?
A: PVC, LSZH and flame-retardant sheaths are optional
Hot Tags: armored control cables, China armored control cables manufacturers, suppliers, factory, Armored Control Cables, Flexible Control Cable, industrial control cables, Multicore Control Cables, Shielded Multicore Control Cable