Offshore Instrumentation Cable

Send Inquiry
Offshore Instrumentation Cable
Details
Exposed to salt spray, high humidity, constant vibration and mechanical stress out at sea. Fine-stranded tinned copper handles flexing from platform movement. Optimized low-capacitance design keeps 4-20mA sensor readings stable. Shielding cuts electrical crosstalk and motor noise. Special offshore-grade sheath fights salt-water corrosion, oil and chemical splashes. Used for monitoring systems, field sensors and control loops on offshore facilities.
Category
Marine Cables
Share to
Description

Products Description

 

Offshore instrumentation cables carry sensor and control signals for offshore platforms and marine installations.

Exposed to salt spray, high humidity, constant vibration and mechanical stress out at sea. Fine-stranded tinned copper handles flexing from platform movement. Optimized low-capacitance design keeps 4-20mA sensor readings stable. Shielding cuts electrical crosstalk and motor noise. Special offshore-grade sheath fights salt-water corrosion, oil and chemical splashes. Used for monitoring systems, field sensors and control loops on offshore facilities.

 

Conductor

Class 5 tinned copper

Cross-section

0.5-2.5 mm²

Temperature Range

-40℃ ~ +70℃

Marine certifications

ABS/DNV/LR/CCS

Insulation resistance

≥2500 MΩ·km

 

Application

 

marine application

 

Certificate

 

ISO Quality Management System Certificate
ABS/DNV/LR/CCS Approved Certificate

 

certificate 04

 

1.Construction

S/N

Construction

Requirement

product-786-556

1

Conductor

2 Class 2 Tinned copper conductor

2

Fire resistance

Mica tape

3

Insulation

XLPE

4

Armor

Tinned copper wire braid

5

Outer Sheath

SHF1

2. Cable identification

Core identification: Black + number code.

1Pairs or more: Black,White

Sheath color: Blue (Or the color required by the customer.)

3. Standard compliance

IEC 60092-376, IEC 60228, IEC 60092-360, IEC 60332-1-2, IEC 60332-3-22, IEC 60754-1~2, IEC 61034-1~2, IEC 60331

4.Application

S/N

Item

Technical requirement

1

Rated voltage

AC 150/250V

2

Operating temperature

'-15~90℃

S/N

No. of cores × sectional area

Structure of conductor

Approx. dia. of conductor

Nominal thk. of insulation

Nominal thk.of sheath

Approx. OD of cable

Approx. weight of cable

 

no.× sqmm

no./mm

mm

mm

mm

mm

kg/km

1

2×1.0

7/0.43

1.29

0.5

1.0

8.6

115

2

4×1.0

7/0.43

1.29

0.5

1.1

10.1

165

3

7×1.0

7/0.43

1.29

0.5

1.1

11.9

223

4

12×1.0

7/0.43

1.29

0.5

1.3

16.2

398

5

19×1.0

7/0.43

1.29

0.5

1.4

19.0

562

6

27×1.0

7/0.43

1.29

0.5

1.5

22.8

759

5. Electrical characteristics

S/N

No. of cores × sectional area ×

Max. DC resistance of conductor@20℃
20℃

Voltage withstand test

 

no.× sqmm

Ω/km

kV/min,no breakdown

1

2×1.0

19.3

1.5/5

2

4×1.0

19.3

1.5/5

3

7×1.0

19.3

1.5/5

4

12×1.0

19.3

1.5/5

5

19×1.0

19.3

1.5/5

6

27×1.0

19.3

1.5/5

 

Huayu Offshore Instrumentation Cable Benefit

 

  • Purpose-built for offshore platforms, delivers clean sensor and control signals in harsh
  • coastal open-sea environments
  • Tuned low-capacitance layout, prevents 4-20mA signal drift even across long-distance field wiring
  • Class 5 high-flex tinned copper, absorbs ongoing platform shake and flex, avoids conductor cracking
  • Individual pair shielding, blocks crosstalk and electrical noise from nearby power equipment
  • Insulation resistance ≥2500 MΩ·km, holds steady performance amid salt mist, high humidity and oil contamination
  • Operating temperature -40℃ ~ +70℃, offshore-formulated sheath stands salt corrosion, oil and chemical splashes
  • Flexible build options: SWA steel wire armour, LSZH, flame-retardant grades to meet offshore project specifications
  • Each lot completes full electrical verification before leaving factory
huayu factory

 

FAQs

 

Q1: What causes most instrumentation cable failures offshore?

A: Most issues come from platform vibration and salt mist eating the sheath. Our offshore-grade cable handles these real-world conditions, helping reduce unplanned downtime and frequent replacements.

Q2: Can nearby power circuits mess up our 4-20mA sensor signals?

A: Pair-shield design helps block outside electrical noise. Low-capacitance build keeps sensor readings stable, even over long cable runs across the platform.

Q3: Do you offer various cable versions for our offshore tender project?

A: We supply SWA armour, LSZH and flame-retardant options. Every batch is electrically tested before shipment to fit offshore site requirements.

 