Products Description
Marine-rated cable is cable certified for use aboard ships and offshore installations. Designed to withstand the unique harsh marine environment for power, control or signal circuits. It must satisfy marine classification society requirements, not ordinary industrial cable.
Key features
- Constructed to resist salt-fog, high humidity, oil and chemical splashes
- Tinned copper conductors are widely used to slow copper corrosion
- Options for shielding, steel wire armour SWA, flame-retardant and LSZH
- Passes marine fire, ageing and environmental tests
- Complies with IEC 60092, approved by DNV, ABS, CCS etc.
|
Conductor |
tinned stranded copper |
|
Cross-section |
0.75 mm², 1.0 mm², 1.5 mm², 2.5 mm², 4 mm², 6 mm², 10 mm² |
|
Temperature Range |
-40℃ ~ +85℃ |
|
Marine certifications |
ABS/DNV/LR/CCS |
|
Insulation resistance |
≥100 MΩ·km @20℃ |
Application

Certificate
ISO Quality Management System Certificate
ABS/DNV/LR/CCS Approved Certificate

|
1.Construction |
|||||||
|
S/N |
Construction |
Requirement |
|
||||
|
1 |
Conductor |
2 Class 2 Tinned copper conductor |
|||||
|
2 |
Insulation |
EPR |
|||||
|
3 |
Individual shield |
+ Aluminum-plastic composite tape + tinned drain wire |
|||||
|
4 |
Overall shield |
+ Aluminum-plastic composite tape + tinned drain wire |
|||||
|
5 |
Inner Sheath |
SHF1(LSZH) |
|||||
|
6 |
Armor |
Tinned copper wire braid |
|||||
|
7 |
Outer Sheath |
Flame retardant, mud resistant SHF1(LSZH) |
|||||
|
2. Cable identification Core identification: Black,White + number code
Sheath color: Grey(Or the color required by the customer.) 3. Standard compliance IEC 60092-376, IEC 60228, IEC 60092-360, IEC 60332-1-2, IEC 60332-3-22, IEC 60754-1~2,IEC 60331 IEC 61034-1~2, NEK TS 606 |
|||||||
|
4.Application |
|||||||
|
S/N |
Item |
Technical requirement |
|||||
|
1 |
Rated voltage |
AC 150/250V |
|||||
|
2 |
Operating temperature |
'-15~90℃ |
|||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/km |
|
|
1 |
1P×1.0 |
7/0.43 |
1.29 |
0.6 |
0.8 |
9.6 |
145 |
|
2 |
2P×1.0 |
7/0.43 |
1.29 |
0.6 |
0.9 |
14.5 |
312 |
|
3 |
12P×1.0 |
7/0.43 |
1.29 |
0.6 |
1.1 |
25.6 |
1006 |
|
5. Electrical characteristics |
|||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
|||||
|
1 |
1P×1.0 |
19.3 |
1.5/5 |
||||
|
2 |
2P×1.0 |
19.3 |
1.5/5 |
||||
|
3 |
12P×1.0 |
19.3 |
1.5/5 |
||||
Huayu 3 Core Tinned Marine Cable Benefit
- Works for auxiliary power and basic control circuits on ships and offshore assets
- Three tinned-cores fight corrosion caused by salty sea-air
- Sturdy insulation holds up in damp, salt-spray and oily onboard spaces
- Heavy-duty outer sheath stands seawater and chemical splashes
- Add overall screen or SWA armour when laying on open deck
- LSZH and flame-retardant versions meet marine class requirements
- Each lot completes full electrical testing prior to shipping

FAQs
Q1: 3-core marine cable is used for?
A: Ideal for small onboard pumps, fans and other low-power auxiliary equipment.
Q2: Is armour always required for marine installation?
A: Not mandatory. SWA armour is only needed for open-deck exposed wiring.
Q3: Can it run instrument 4-20mA signals?
A: Not recommended. This cable is built for power and simple control, not instrument signal transmission.
Hot Tags: marine rated cable, China marine rated cable manufacturers, suppliers, factory