Products Description
Marine Boat Cable for Onboard Electrical Systems
Marine boat cable is used for electrical circuits on boats, yachts and other vessels. This cable range is designed for onboard power wiring where the cable may need to pass through compact spaces, equipment areas and different sections of the vessel.
The cable uses tinned copper conductor, XLPE insulation and SHF1 outer sheath. It is available in different core configurations and conductor sizes for power supply, lighting, auxiliary equipment and other onboard electrical circuits.
A Practical Choice for Boat Wiring
Boat wiring often has to work around panels, machinery, bulkheads and other equipment. A suitable cable construction makes routing and connection easier, especially when several electrical circuits are installed in the same area.
The 0.6/1 kV rating gives this cable a wider application range than low-voltage boat wiring used only for small auxiliary circuits. It can be used for both equipment power supply and general onboard electrical distribution, depending on the vessel design.
Where It Is Used
- Boat and yacht electrical systems
- Workboats and service vessels
- Onboard lighting and auxiliary circuits
- Pumps, fans and other marine equipment
- Distribution wiring between marine electrical panels and equipment
One Cable Range, Different Vessel Requirements
A small yacht, a workboat and a larger commercial vessel do not have the same cable requirements. Conductor size, number of cores and installation conditions can vary considerably.
Huayu supplies marine boat cable in a wide range of sizes and configurations. This makes it easier to select the cable according to the actual circuit rather than forcing different applications into one standard size.
Marine Standards
The cable is manufactured according to applicable IEC 60092 marine cable requirements, with relevant flame-retardant and low-smoke, halogen-free properties. Marine type approval and certification documents are available for applicable products and projects.
Application

Certificate
ISO Quality Management System Certificate
ABS/DNV/LR/CCS Approved Certificate

|
1.Construction |
||||||||
|
S/N |
Construction |
Requirement |
|
|||||
|
1 |
Conductor |
2 Class 2 Tinned copper conductor |
||||||
|
2 |
Insulation |
XLPE |
||||||
|
3 |
Inner Sheath |
SHF1 |
||||||
|
4 |
Armor |
Tinned copper wire braid |
||||||
|
5 |
Outer Sheath |
SHF1 |
||||||
|
2. Cable identification Core identification: 1C: Natural. 2C: Brown,Blue. 2C+E: Brown,Blue,Green/Yellow. 3C: Brown,Black,Blue. 3C+E: Brown,Black,Grey,Green/Yellow. 4C: Blue,Brown,Black,Grey. 7C or more: Black + number code. Sheath color: Black(Or the color required by the customer.) 3. Standard compliance IEC 60092-353, IEC 60228, IEC 60092-360, IEC 60332-1-2, IEC 60332-3-22, IEC 60754-1~2, IEC 61034-1~2 |
||||||||
|
4.Application |
||||||||
|
S/N |
Item |
Technical requirement |
||||||
|
1 |
Rated voltage |
AC 0.6/1kV |
||||||
|
2 |
Operating temperature |
'-15~90℃ |
||||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
|
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/km |
||
|
1 |
1×4 |
7/0.85 |
2.50 |
0.7 |
0.8 |
8.1 |
116 |
1 |
|
2 |
1×50 |
19/1.76 |
8.30 |
1.0 |
0.9 |
15.5 |
652 |
2 |
|
3 |
1×70 |
19/2.12 |
10.20 |
1.1 |
1.0 |
18.0 |
900 |
3 |
|
4 |
2×1.5 |
7/0.52 |
1.56 |
0.7 |
0.8 |
10.8 |
163 |
4 |
|
5 |
2×2.5 |
7/0.68 |
2.04 |
0.7 |
0.8 |
11.8 |
204 |
5 |
|
6 |
2×4 |
7/0.85 |
2.50 |
0.7 |
0.9 |
13.0 |
256 |
6 |
|
7 |
2×6 |
7/1.04 |
3.04 |
0.7 |
0.9 |
14.4 |
347 |
7 |
|
8 |
2×10 |
7/1.35 |
3.80 |
0.7 |
0.9 |
16.2 |
470 |
8 |
|
9 |
2×16 |
7/1.7 |
4.80 |
0.7 |
1.0 |
18.6 |
648 |
9 |
|
10 |
2×25 |
7/2.12 |
6.20 |
0.9 |
1.1 |
22.6 |
944 |
10 |
|
11 |
2×35 |
7/2.5 |
7.20 |
0.9 |
1.1 |
24.8 |
1198 |
11 |
|
12 |
2×50 |
19/1.76 |
8.30 |
1.0 |
1.2 |
27.8 |
1533 |
12 |
|
13 |
2×70 |
19/2.12 |
10.20 |
1.1 |
1.3 |
32.4 |
2108 |
13 |
|
14 |
2×120 |
37/2.02 |
13.40 |
1.2 |
1.5 |
40.7 |
3528 |
14 |
|
15 |
2×1.5+1.5 |
7/0.52 |
1.56 |
0.7 |
0.8 |
11.3 |
186 |
15 |
|
16 |
2×2.5+2.5 |
7/0.68 |
2.04 |
0.7 |
0.9 |
12.5 |
243 |
16 |
|
17 |
2×10+10 |
7/1.35 |
3.80 |
0.7 |
1.0 |
17.2 |
587 |
17 |
|
18 |
2×50+50 |
19/1.76 |
8.30 |
1.0 |
1.3 |
29.8 |
2022 |
18 |
|
19 |
2×120+120 |
37/2.02 |
13.40 |
1.2 |
1.6 |
43.5 |
4711 |
19 |
|
20 |
3×1.5 |
7/0.52 |
1.56 |
0.7 |
0.8 |
11.3 |
186 |
20 |
|
21 |
3×2.5 |
7/0.68 |
2.04 |
0.7 |
0.9 |
12.5 |
243 |
21 |
|
22 |
3×4 |
7/0.85 |
2.50 |
0.7 |
0.9 |
14.0 |
338 |
22 |
|
23 |
3×6 |
7/1.04 |
3.04 |
0.7 |
0.9 |
15.3 |
427 |
23 |
|
24 |
3×10 |
7/1.35 |
3.80 |
0.7 |
1.0 |
17.2 |
587 |
24 |
|
25 |
3×16 |
7/1.7 |
4.80 |
0.7 |
1.0 |
19.6 |
816 |
25 |
|
26 |
3×25 |
7/2.12 |
6.20 |
0.9 |
1.1 |
23.8 |
1199 |
26 |
|
27 |
3×35 |
7/2.5 |
7.20 |
0.9 |
1.2 |
26.4 |
1557 |
27 |
|
28 |
3×50 |
19/1.76 |
8.30 |
1.0 |
1.3 |
29.8 |
2022 |
28 |
|
29 |
3×70 |
19/2.12 |
10.20 |
1.1 |
1.4 |
34.9 |
2807 |
29 |
|
30 |
3×95 |
19/2.5 |
12.10 |
1.1 |
1.5 |
39.7 |
3801 |
30 |
|
31 |
3×120 |
37/2.02 |
13.40 |
1.2 |
1.6 |
43.5 |
4711 |
31 |
|
32 |
3×150 |
37/2.25 |
14.90 |
1.4 |
1.7 |
48.0 |
5761 |
32 |
|
33 |
3×1.5+1.5 |
7/0.52 |
1.56 |
0.7 |
0.9 |
12.4 |
227 |
33 |
|
34 |
3×2.5+2.5 |
7/0.68 |
2.04 |
0.7 |
0.9 |
13.4 |
287 |
34 |
|
35 |
3×35+35 |
7/2.5 |
7.20 |
0.9 |
1.2 |
28.9 |
1963 |
35 |
|
36 |
4×1.5 |
7/0.52 |
1.56 |
0.7 |
0.9 |
12.4 |
227 |
36 |
|
37 |
4×2.5 |
7/0.68 |
2.04 |
0.7 |
0.9 |
13.4 |
287 |
37 |
|
38 |
7×1.5 |
7/0.52 |
1.56 |
0.7 |
0.9 |
14.6 |
334 |
38 |
|
39 |
10×1.5 |
7/0.52 |
1.56 |
0.7 |
1.0 |
18.0 |
459 |
39 |
|
5. Electrical characteristics |
||||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
|||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
||||||
|
1 |
1×4 |
4.70 |
3.5/5 |
|||||
|
2 |
1×50 |
0.391 |
3.5/5 |
|||||
|
3 |
1×70 |
0.270 |
3.5/5 |
|||||
|
4 |
2×1.5 |
12.2 |
3.5/5 |
|||||
|
5 |
2×2.5 |
7.56 |
3.5/5 |
|||||
|
6 |
2×4 |
4.70 |
3.5/5 |
|||||
|
7 |
2×6 |
3.11 |
3.5/5 |
|||||
|
8 |
2×10 |
1.84 |
3.5/5 |
|||||
|
9 |
2×16 |
1.16 |
3.5/5 |
|||||
|
10 |
2×25 |
0.734 |
3.5/5 |
|||||
|
11 |
2×35 |
0.529 |
3.5/5 |
|||||
|
12 |
2×50 |
0.391 |
3.5/5 |
|||||
|
13 |
2×70 |
0.270 |
3.5/5 |
|||||
|
14 |
2×120 |
0.154 |
3.5/5 |
|||||
|
15 |
2×1.5+1.5 |
12.2 |
3.5/5 |
|||||
|
16 |
2×2.5+2.5 |
7.56 |
3.5/5 |
|||||
|
17 |
2×10+10 |
1.84 |
3.5/5 |
|||||
|
18 |
2×50+50 |
0.391 |
3.5/5 |
|||||
|
19 |
2×120+120 |
0.154 |
3.5/5 |
|||||
|
20 |
3×1.5 |
12.2 |
3.5/5 |
|||||
|
21 |
3×2.5 |
7.56 |
3.5/5 |
|||||
|
22 |
3×4 |
4.70 |
3.5/5 |
|||||
|
23 |
3×6 |
3.11 |
3.5/5 |
|||||
|
24 |
3×10 |
1.84 |
3.5/5 |
|||||
|
25 |
3×16 |
1.16 |
3.5/5 |
|||||
|
26 |
3×25 |
0.734 |
3.5/5 |
|||||
|
27 |
3×35 |
0.529 |
3.5/5 |
|||||
|
28 |
3×50 |
0.391 |
3.5/5 |
|||||
|
29 |
3×70 |
0.270 |
3.5/5 |
|||||
|
30 |
3×95 |
0.195 |
3.5/5 |
|||||
|
31 |
3×120 |
0.154 |
3.5/5 |
|||||
|
32 |
3×150 |
0.126 |
3.5/5 |
|||||
|
33 |
3×1.5+1.5 |
12.2 |
3.5/5 |
|||||
|
34 |
3×2.5+2.5 |
7.56 |
3.5/5 |
|||||
|
35 |
3×35+35 |
0.529 |
3.5/5 |
|||||
|
36 |
4×1.5 |
12.2 |
3.5/5 |
|||||
|
37 |
4×2.5 |
7.56 |
3.5/5 |
|||||
|
38 |
7×1.5 |
12.2 |
3.5/5 |
|||||
|
39 |
10×1.5 |
12.2 |
3.5/5 |
|||||
Huayu Marine Boat Cable Benefit
- Built for boat and small vessel auxiliary power & simple control circuits
- Multi-core tinned copper stops corrosion from salty marine air
- Solid insulation performs well in damp, salt-spray and oily areas
- Marine-grade outer sheath copes with seawater and chemical splashes
- Option for overall screen and SWA armour for open-deck use
- LSZH / flame-retardant grades available to meet marine classification rules
- Every lot gets full electrical tests before shipment

FAQs
Q1: What vessels is this cable suitable for?
A: For yachts, fishing boats, work boats and various small marine vessels.
Q2: Why adopt tinned copper conductor?
A: Tinned copper effectively prevents corrosion caused by salt-spray onboard environment.
Q3: Is armour required for cabin internal wiring?
A: Armour is optional; SWA armour is recommended for exposed open-deck installation.
Hot Tags: marine boat cable, China marine boat cable manufacturers, suppliers, factory