Products Description
Multi-core cable for low-voltage control & measurement signals.
It links sensors and field instruments, not for high-power power supply.
Marine types ( CKJP86/SC) feature oil-resistance, moisture resistance and flame retardancy, with ABS / DNV / LR approvals for ship and offshore platform deployment.
Signal-focused multicore cable for instrument circuits. Marine-approved variants for vessel & offshore use.
|
Core quantity |
2-7 cores |
|
Conductor |
1.0-95 mm² |
|
Temperature Range |
-20℃ ~ +80℃ |
|
Marine certifications |
ABS/DNV/LR |
|
Usage scenario |
Vessels, offshore platforms |
Application

Certificate
ISO Quality Management System Certificate
ABS/DNV/LR/CCS Approved Certificate

|
1.Construction |
|||||||
|
S/N |
Construction |
Requirement |
|
||||
|
1 |
Conductor |
2 Class 2 copper conductor |
|||||
|
2 |
Insulation |
XLPE |
|||||
|
3 |
Overall shield |
+ Copper-plastic composite tape + drain wire |
|||||
|
4 |
Isolation |
PVC |
|||||
|
5 |
Armor |
Galvanized steel wire armor |
|||||
|
6 |
Sheath |
Rodent and ant proof, Flame Retardant PVC |
|||||
|
2. Cable identification Core identification: Single twisted pair: Red, White Multiple twisted pairs: Red, White + number code Sheath color: Black 3. Standard compliance GB/T 34016-2017, IEC 60332-3-22, TICW/06-2009, Q/WHY 09 |
|||||||
|
4.Application |
|||||||
|
S/N |
Item |
Technical requirement |
|||||
|
1 |
Rated voltage |
AC 300/500V |
|||||
|
2 |
Operating temperature |
'-15~90℃ |
|||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/km |
|
|
1 |
1×2×2.5 |
7/0.68 |
2.0 |
0.6 |
1.1 |
12.1 |
279 |
|
2 |
5×2×2.5 |
7/0.68 |
2.0 |
0.6 |
1.4 |
24.2 |
1169 |
|
5. Electrical characteristics |
|||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
|||||
|
1 |
1×2×2.5 |
7.41 |
1/1 |
||||
|
2 |
5×2×2.5 |
7.41 |
1/1 |
||||
Huayu Multicore Instrumentation Cable Benefit
- High-performance shielding to block EMI from ship-mounted motors and power equipment
- Low capacitance, maintains reliable 4-20mA signals over long ship-board runs
- Class 5 tinned copper conductors, flexible for tight cabin spaces and repeated bending
- Good crosstalk rejection, prevents interference between individual cores
- Insulation resistance ≥5000MΩ·km, low signal leakage for long offshore service life
- Operating range -20℃ ~ +80℃; resistant to salt-fog, oil and moisture
- Flame-retardant construction, suitable for vessels and offshore platforms
- ABS, DNV, LR marine society certifications; every batch tested prior to shipment

FAQs
Q1: What certifications do you have?
A: It holds ABS, DNV and LR marine classification approvals, fully qualified for ship and offshore platform installation.
Q2: Can this cable transmit 4-20mA signals over long distances?
A: Yes. It supports stable 4-20mA signal transmission for marine field instrument loops.
Q3: What working environments is suited for?
A: It fits narrow cabin wiring, tolerates salt-fog, oil and damp conditions, and works within -20℃ ~ +80℃.
Hot Tags: multicore instrumentation cable, China multicore instrumentation cable manufacturers, suppliers, factory, 4 Pair Instrument Cable, Armored Instrument Cable, BS5308 Instrumentation Cable, Fire Rated Instrumentation Cable, instrumentation cables, Multipair Instrumentation Cable