Shielded Instrumentation Cable

Send Inquiry
Shielded Instrumentation Cable
Details
The built-in shielding layer effectively resists external electromagnetic interference, ensures stable and accurate signal transmission. It is widely applied in industrial automation, chemical, power and other complex working environments.
Category
Instrumentation Cables
Share to
Description

Products Description

 

Shielded instrumentation cable is a special industrial signal cable. It is mainly used to connect sensors, transmitters and control systems such as PLC and DCS.
The built-in shielding layer effectively resists external electromagnetic interference, ensures stable and accurate signal transmission. It is widely applied in industrial automation, chemical, power and other complex working environments.

 

Rated Voltage

300/500V

Conductor

0.5mm², 0.75mm², 1.0mm², 1.5mm²

Temperature Range

-20℃ ~ +80℃

Standards

IEC 60227, IEC 61034

Core structure

multi-pair, multi-core

 

Application

 

application

 

Certificate

 

ISO Quality Management System Certificate
Verification to IEC 60227-5:2024,
EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021

 

certificate 05

 

1.Construction

S/N

Construction

Requirement

product-654-437

1

Conductor

2 Class 2 copper conductor

2

Insulation

XLPE

3

Overall shield

+ Copper-plastic composite tape + drain wire

4

Isolation

PVC

5

Armor

Galvanized steel wire armor

6

Sheath

Rodent and ant proof, Flame Retardant PVC

2. Cable identification

Core identification: Single twisted pair: Red, White

Multiple twisted pairs: Red, White + number code

Sheath color: Black

3. Standard compliance

GB/T 34016-2017, IEC 60332-3-22, TICW/06-2009, Q/WHY 09

4.Application

S/N

Item

Technical requirement

1

Rated voltage

AC 300/500V

2

Operating temperature

'-15~90℃

S/N

No. of cores × sectional area

Structure of conductor

Approx. dia. of conductor

Nominal thk. of insulation

Nominal thk.of sheath

Approx. OD of cable

Approx. weight of cable

 

no.× sqmm

no./mm

mm

mm

mm

mm

kg/km

1

1×2×2.5

7/0.68

2.0

0.6

1.1

12.1

279

2

5×2×2.5

7/0.68

2.0

0.6

1.4

24.2

1169

5. Electrical characteristics

S/N

No. of cores × sectional area ×

Max. DC resistance of conductor@20℃
20℃

Voltage withstand test

 

no.× sqmm

Ω/km

kV/min,no breakdown

1

1×2×2.5

7.41

1/1

2

5×2×2.5

7.41

1/1

 

Huayu Shielded Instrumentation Cable Benefit

 

  • 70dB+ shielding effectiveness, resists EMI from motors and power equipment
  • Capacitance ≤200pF/100m, stable 4-20mA signal up to 800m
  • Class 5 tinned copper, supports RS485 transmission up to 1200m
  • Over 55dB crosstalk suppression for multi-pair signal separation
  • Insulation resistance ≥5000MΩ·km, low signal leakage for long-term use
  • Operates -20℃~+80℃, flame-retardant & LSZH options available
  • Full-batch testing before delivery for consistent signal performance
huayu factory

 

FAQs

 

1.When should I consider shielded instrumentation cable?

Pick shielded version if cables run close to power cables, motors or VFD equipment. The shield helps avoid signal interference for 4-20mA, RS485 instrument loops.

2.What is the difference between overall shield and individual pair shield?

Overall shield covers the whole cable, cost-effective for general sites. Individual pair shield gives better crosstalk reduction, used for multi-pair high-precision signal wiring.

3.What is the maximum transmission distance for instrumentation cable?

For 4-20mA analog signal, stable run up to 800m; for RS485 communication, max reach 1200m under proper installation conditions.

 

Hot Tags: shielded instrumentation cable, China shielded instrumentation cable manufacturers, suppliers, factory, 4 Pair Instrument Cable, BS5308 Instrumentation Cable, Fire Rated Instrumentation Cable, Industrial Instrumentation Cable, Instrument Pair Cable, Shielded Instrumentation Cable