Products Description
BS 5308 is a British industry standard for instrumentation cables, commonly seen in process plants and marine installations.
It covers both multicore and multipair cable types, mainly for low-level control signals like 4-20mA. This standard sets clear requirements for shielding, capacitance, insulation resistance and crosstalk, to preserve signal quality where electromagnetic noise is high.
Cables complying with BS 5308 are widely used on vessels and offshore units. Different shielding options are available to match site anti-interference needs.
|
Conductor |
Class 5 tinned copper |
|
Cross-section |
0.5-2.5 mm² |
|
Temperature Range |
-40℃ ~ +70℃ |
|
Marine certifications |
ABS/DNV/LR/CCS |
|
Usage scenario |
offshore and vessel instrument signal loops |
Application

Certificate
ISO Quality Management System Certificate
ABS/DNV/LR/CCS Approved Certificate

|
1.Construction |
|||||||
|
S/N |
Construction |
Requirement |
|
||||
|
1 |
Conductor |
1 Class 1 copper conductor |
|||||
|
2 |
Fire resistance |
Mica tape |
|||||
|
3 |
Insulation |
XLPE |
|||||
|
4 |
Metal shield |
Aluminum polyester composite film |
|||||
|
5 |
Inner sheath |
LSZH |
|||||
|
6 |
Armor |
Galvanized steel wire armor |
|||||
|
7 |
Sheath |
LSZH |
|||||
|
2. Cable identification Core identification: White insulation printed with black digits Sheath color: Black 3. Standard compliance GB/T9330-2020 |
|||||||
|
4.Application |
|||||||
|
S/N |
Item |
Technical requirement |
|||||
|
1 |
Rated voltage |
AC 300/500V |
|||||
|
2 |
Operating temperature |
'-15~90℃ |
|||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/m |
|
|
1 |
12×2.5 |
1/1.76 |
1.76 |
0.7 |
1.7 |
26.0 |
1.269 |
|
5. Electrical characteristics |
|||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
|||||
|
1 |
12×2.5 |
7.41 |
3/5 |
||||
Huayu BS 5308 Instrumentation Cable Benefit
- Fully built to BS 5308 standard for industrial & marine signal circuits
- Controlled low-capacitance, stable 4-20mA signal over long cable runs
- Class 5 tinned copper conductors, fits tight routing and repeated bending
- Good crosstalk rejection, minimizes interference between cores and pairs
- Insulation resistance ≥2500MΩ·km, reliable for long-term service
- Operating range -40℃ ~ +70℃, oil and moisture resistant Optional SWA armour, LSZH and flame-retardant sheath Every batch electrically tested for consistent performance

FAQs
Q1: What BS 5308 instrumentation cable used for?
A: It is used for 4-20mA instrument signal loops in factories, vessels and offshore facilities.
Q2: Do you offer extra options can I get with this cable?
A: SWA armour, LSZH and flame-retardant sheaths are available for harsh environments.
Q3: What electrical tests are done before delivery?
A: Each batch gets full electrical checks to meet BS 5308 performance requirements.
Hot Tags: bs5308 instrumentation cable, China bs5308 instrumentation cable manufacturers, suppliers, factory