Products Description
Conductor and Flexibility
5 class 5 copper conductor, made up of many fine strands rather than a rigid core. This makes it much easier to pull through tight conduit or route around bends in a crowded trench, and it reduces the risk of insulation stress from forced bending during installation.
Fire Resistance and Temperature Rating
A mica tape layer sits under the insulation as a fire barrier. Combined with X-HF-110 (XLPO) insulation, the cable is rated for continuous operation up to 110°C - a real margin over standard 90°C cable when it's routed through a poorly ventilated tunnel or a hot industrial area.
Low Smoke Zero Halogen Sheath
The HFS-110-TP (LSZH) outer sheath produces minimal smoke and no halogen acid gas if it burns. That keeps visibility and air quality better during an evacuation, which is why LSZH is the default choice for subways, basements, and other enclosed public spaces.
Standards and Core Identification
Manufactured to AS/NZS 5000.1, AS/NZS 1125, AS/NZS 3808, and AS/NZS 3013. Core colors follow AS/NZS convention: red/white for 2-core, red/white/blue/black/green-yellow for 4-core+earth - matches what most Australian and New Zealand project specs ask for directly.
Where It's Used
Urban tunnels, underground utility runs, and industrial pump stations - anywhere space is tight and fire risk matters. The flexible conductor cuts installation time in cramped trenches, and the 110°C rating gives it headroom under sustained heavy load without derating.
Manufacturing and Certification
We adjusted the extrusion process specifically for this flexible stranded conductor, so the insulation bonds tightly to the strands instead of leaving small gaps where moisture can wick in over time - a common weak point in lower-grade flexible cable. This batch holds DNV and ABS type approval for this exact cable construction, and every reel is voltage-tested and resistance-tested before it ships, with reports kept on file.
Application

Certificate
ISO Quality Management System Certificate
IEC 60502-1:2020, EN IEC 61000-6-1:2019,
EN IEC 61000-6-3:2021

|
1.Construction |
||||||||
|
S/N |
Construction |
Requirement |
|
|||||
|
1 |
Conductor |
5 Class 5 Copper conductor |
||||||
|
2 |
Fire resistance |
Mica tape |
||||||
|
3 |
Insulation |
X-HF-110(XLPO) |
||||||
|
4 |
Sheath |
HFS-110-TP(LSZH) |
||||||
|
2. Cable identification Core identification: 1C: natural color 2C: Red, White 4C+E: Red, White, Blue, Black, Green/Yellow 3. Standard compliance AS/NZS 5000.1, AS/NZS 1125, AS/NZS 3808, AS/NZS 3013 |
||||||||
|
4.Application |
||||||||
|
S/N |
Item |
Technical requirement |
||||||
|
1 |
Rated voltage |
AC 0.6/1(1.2)kV |
||||||
|
2 |
Operating temperature |
'-15~110℃ |
||||||
|
S/N |
No. of cores × sectional area |
Structure of conductor |
Approx. dia. of conductor |
Nominal thk. of insulation |
Nominal thk.of sheath |
Approx. OD of cable |
Approx. weight of cable |
Sheath color |
|
no.× sqmm |
no./mm |
mm |
mm |
mm |
mm |
kg/km |
/ |
|
|
1 |
1×70 |
518/0.40 |
11.0 |
1.1 |
1.4 |
17.7±1.5 |
776 |
Black |
|
2 |
1×240 |
1147/0.50 |
20.5 |
1.7 |
1.7 |
29.0±2.0 |
2411 |
Orange |
|
3 |
1×300 |
1403/0.50 |
23.2 |
1.8 |
1.8 |
32.1±2.5 |
2979 |
Orange |
|
4 |
2×70 |
518/0.40 |
11.0 |
1.1 |
1.8 |
32.8±2.5 |
1609 |
Orange |
|
5 |
4×70+1×35 |
518/0.40,259/0.40 |
11.0/7.4 |
1.1/0.9 |
2.1 |
40.4±3.0 |
3588 |
Orange |
|
5. Electrical characteristics |
||||||||
|
S/N |
No. of cores × sectional area × |
Max. DC resistance of conductor@20℃ |
Voltage withstand test |
|||||
|
no.× sqmm |
Ω/km |
kV/min,no breakdown |
||||||
|
1 |
1×70 |
0.272 |
3.5/5 |
|||||
|
2 |
1×240 |
0.0801 |
3.5/5 |
|||||
|
3 |
1×300 |
0.0641 |
3.5/5 |
|||||
|
4 |
2×70 |
0.272 |
3.5/5 |
|||||
|
5 |
4×70+1×35 |
0.272/0.554 |
3.5/5 |
|||||
Huayu Low Voltage Underground Cable Benefit
- Designed for buried industrial & building low-voltage power circuits
- Multi-core copper conductors withstand damp soil and coastal conditions -Durable insulation works well in wet, corrosive underground environments
- Heavy-duty outer sheath resists moisture and soil corrosion
- Optional SWA steel wire armour against impact, crushing and rodent damage
- LSZH / flame-retardant options meet local safety standards
- Each batch completes full electrical tests before delivery

FAQs
Q: Does the flexible Class 5 conductor shorten the cable's life in damp soil?
A: Not if the sheath stays intact. If anything, the flexibility helps - it gives the cable some give when the soil settles slightly, instead of cracking the way a rigid conductor might under the same stress.
Q: Can this replace rigid mineral-insulated (MICC) cable?
A: For most applications where the concern is smoke and flame spread rather than surviving direct flame at extreme temperature, yes - this cable meets AS/NZS 3013 fire performance and is considerably easier and cheaper to install than MICC.
Q: Is this cable suitable for direct burial?
A: Yes, that's its intended use. If it runs through a section with its own fire compartment rating, check that rating against this cable's LSZH and mica tape performance rather than assuming general underground cable is automatically compliant.
Hot Tags: low voltage underground cable, China low voltage underground cable manufacturers, suppliers, factory